Calculation of Power Required For Pumping
Flow Rate , Q= 83.33 kg/sec
Density of Medium, l= 1000kg/m3
Pump Head Required, H= 25m
Pump Efficency, η=0.75
Pump Power Required, P = (Flow Rate *Required Pump Head)/(Efficiency)
=(83.33*25)/0.75
=2777.667 kg m/sec
=37.00 hp